Pathology Handbook

 New search
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z # ALL

Anti Xa for Fragmin Therapy

Laboratory:Haematology
Test Code:A10A-FRA
Specimen Types:Plasma
Container Types:
Sodium Citrate
Adults Volume or Mass:2.7 mL
Collection & Request Instructions:Add exactly 2.7 mL of blood & mix by inversion.
A pre–dose level should be measured when the creatinine clearance is known or estimated to be below 0.5 mL/sec. If the pre–dose level is at the higher end or above the reference range, please discuss with the Haematologist (Ext. 63075). Must provide details of anticoagulant in use. Mark request as "Priority".
Specimens cannot be analysed or re-analysed greater than 2 hours after collection.
When the collection is by vacuum tube,the coagulation tube should be collected second to avoid artefactual shortening of coagulation assays due to the trauma of venesection.  When syringes are used, have ready two plastic syringes. A butterfly needle may be used. Withdraw 5 mL blood into the first syringe and discard the syringe (or use it for other tests). With the second syringe, withdraw the required amount of blood for the coagulation tests. When blood is collected from an arterial line it is necessary to discard the first 20mL of blood to clear any heparin from the line before collecting the blood for coagulation tests.
Transport Instructions between Sites and/or Laboratories:Room Temperature
Additional Notes:

Reference Range: 0.50—1.00 IU/mL